A SERVICE OF

logo

The passwords do not work or you forgot a password.
Steps to Take:
1. Enter force at the password prompt. Then press the ATM Reset button on the
front panel of the 6416SW module within 3 seconds. This will reboot the 6416SW
to the factory default settings.
When you turn ON the hub, your last configuration settings are not loaded. A
different configuration is activated.
Steps to Take:
1. Re-enter the configuration settings and save them using the SAVE command.
The >> prompt appears on the screen and you have not entered the MAINTAIN
command.
Steps to Take:
1. The 6416SW module is running in maintenance mode. To return to normal
operation mode, enter the BOOT command. This resets the ATM subsystem.
The >>
abcd
>> prompt appears, where
a,b,c,d
are 4 hexadecimal digits.
Steps to Take:
1. The 6416SW entered maintenance mode because of an error, which is indicated by
the error-code prompt. Refer to “Maintenance Codes” on page C-5 for the meaning
of the code, and take the corrective steps required.
7-13