Extron electronic 68-2378-01 Stereo Equalizer User Manual


 
Command ASCII (Telnet)
(host to processor)
URL Encoded (Web)
(host to processor)
Response
(processor to host)
Ethernet data port
Set current conn port time-out
E 0*X16(TC} W0%2AX16(TC
|
Pti0*X16(]
View current conn port time-
out
E 0TC} W0TC
|
X16(]
Set global IP port time-out
E 1*X16(TC} W1%2AX16(TC
|
Pti1*X16(]
View global IP conn port time-
out
E 1TC} W1TC
|
X16(]
Re-map port designations
Set Telnet port map
EX10!MT} WX10!MT
|
PmtX10!]
Reset Telnet port map
E23MT} W23MT
|
Pmt00023]
Disable Telnet port map
E0MT} W0MT
|
Pmt00000]
Read Telnet port map
EMT} WMT
|
X10!]
Directories
Change/create directory
E{path}/{directory}/CJ} W {path}/{directory}/CJ| Dir•{path}/{directory}/]
NOTE: A directory does not actually exist until a file has been copied into the path.
Move back to root directory
E / CJ} W%2FCJ| Dir•/]
Move up one directory
E ..CJ} W%2E%2ECJ|
Dir•{path}/
{directory}/]
View current directory
E CJ} WCJ| {path}/{directory}/]
NOTE:
X10! = Specific port number (01-99), 00 = reserved
X16(
= Time-out in 10 second steps,, 1-65000 (default = 30 = 30 seconds)
Annotator 300 • SIS Communication and Control 61