Command ASCII command
(host to processor)
Response
(processor to host)
Additional description
USB driver commands
List user loaded driver
files
ELUSBF} <lename>]<lename>]
...<lename>]]
Delete user loaded driver
files
ED<lename>USBF} UsbfD
<lename>]
Time zone
Set time zone
E<zone name>*TZON} Tzon
<zone name> * <description>]
View current time zone
ETZON} <zone name> * <description>]
List all time zone
E*TZON} <zone name> * <description>]
<zone name> * <description>]
<zone name> * <description>]
Resets
Erase user-supplied web
pages and files
E<lename>EF} Del<lename>]
Erase current directory
and files
E/EF} Ddl]
Erase current directory
and subdirectories
E//EF} Ddl]
Erase flash memory
EZFFF} Zpf]
Reset all device settings
to factory default settings
EZXXX} Zpx]
Absolute system reset
EZQQQ} Zpq]
Includes resetting IP to
192.168.254.254 and subnet mask to
255.255.000.000.
Absolute system reset
(but retain IP)
EZY} Zpy]
NOTE: This reset is similar to ZQQQ but excludes IP address, subnet mask, gateway addresses, unit name, DHCP
setting, and port mapping (telnet/web/direct access) in order to maintain communications with device. Recommended
after a firmware update.
Information request
General information
I/i
VidX!TypX%StdX1!BlkX1)HrtX1#VrtX1#]
Query firmware version
Q/q
x.xx]
View firmware version.
Query part number
N/n
zz-zzz-zz]
View part number.
View internal
temperature
E 20STAT} X1@]
Temperature in degrees Celsius.
Backup/Restore configuration
Save box configuration
to file system
E1*X7*XF} Cfg1*X7*]
Backup the current device
configuration
Restore configuration
from file system
E0*X7*XF} Cfg0*X7*]
Restore device configuration
NOTE: X! = Input selection, 1 to 3
X% = Detected Input Video Format: 0 = No signal present, 1 = RGB, 2 = Auto YUV, 3 = RGBcvS, 4 = S-Video,
5 = Composite, 6 = DVI, 7 = HDMI, 8 = DisplayPort
X1) = off/disable (0), on/enable (1)
X1! = Input standard: 0 = No signal, 1 = NTSC, 2 = PAL, 3 = SECAM, - = N/A (when input is set to a high
resolution signal format)
X1@ = Internal temperature (in degrees Celsius)
X1# = Horizontal and vertical frequencies (format is three digit with single decimal and leading zeros<
for example, 075.3)
X7* = Configuration type: 0 = IP config, 1 = Event config, 2 = Box config