Extron electronic 68-2378-01 Stereo Equalizer User Manual


 
Output, User Interface, and Control Connections
E
HDMI connectors — Connect suitable HDMI or DVI (with an adapter) displays
to these two connectors for HDMI or DVI output.
F
RJ-45 connector — Connect the Annotator 300 to a DTP receiver for selectable
DTP or HDBaseT output that supports the digital signal transmission of HDMI
with embedded audio and control up to 330 feet (100 meters) over shielded
twisted pair (STP) cable. Output format is selected by setting the switch
accordingly.
CAUTION: Risk of damage to equipment. DO NOT connect an HDBaseT unit if
using DTP transmission. The power carried over DTP may damage the unit.
ATTENTION: Cela risque d’endommager votre équipement. Ne PAS connecter
une unité HDBaseT si vous utilisez la transmission DTP. L’alimentation transmise
sur DTP peut endommager l’unité.
G
5-pole captive screw connector — Connect to this for bi-directional RS-232
over DTP and IR insertion.
H
USB A ports — Connect up to twenty touch panel devices (using USB hubs), or
a USB mouse and keyboard to these ports.
I
Reset button and LED — This button is used to reset the switcher to any one
of four different states. The LED indicates the status during the procedure.
Refer to the Resetting the Unit with the Reset Button” section, for details.
J
RJ-45 Ethernet connector — Connect the Annotator 300 to Ethernet LAN or
WAN via this RJ-45 connector. Ethernet control allows the operator to control the
processor from a remote location. When connected to an Ethernet LAN or WAN,
the device can be accessed and operated from a computer running a standard
Internet browser. The Link LED lights green when the Annotator 300 is connected
to an Ethernet LAN, and the Act LED flickers amber, indicating data transmission
as the devices communicate.
K
RS-232 3-pole captive screw connector — This connector provides for
two-way RS-232 communication. Connect a host computer or control system to
this for serial RS-232 or RS-422 control. The default protocol is 9600 baud,
1 stop bit, no parity, and no flow control.
L
Remote contact closure 3-pole captive screw connector — Connect a host
device to this 3-pole connector for remote contact closure control.
9Annotator 300 • Rear Panel Features and Connections