Nortel Networks BCM1000 Stereo System User Manual


 
Chapter 7 Setting media bay module DIP switches 95
Installation and Maintenance Guide
CTM/GATM DIP switch settings
Table 17 shows the switch settings for each DS30 bus, and the resulting line assignments for
CTMs/GATM4s and CTM8s/GATM8s.
Table 17 CTM/GATM4 and CTM8/GATM8 DS30 and offset switch settings
Select
DS30
bus #
Select
offset
Enter these switch settings To assign
these lines
To assign these lines.
CTM8/GATM8
123456
CTM/GATM4
Lower
(Lines 1-4)
Upper
(lines 5-8)
02
0
on on on on on on
211-214 211-214 219-222
1
on on on on on
219-222 219-222 227-230
off
2
on on on on on
227-230 227-230 235-238
off
3
on on on on
235-238 Not supported Not supported
off off
03
0
on on on on on
181-184
181-184 189-192
off
1
on on on on
189-192
189-192 197-200
off off
2
on on on on
197-200
197-200 205-208
off off
3
on on on
205-208
Not supported Not supported
off off off
04
0
on on on on on
151-154
151-154 159-162
off
1
on on on on
159-162
159-162 167-170
off off
2
on on on on
167-170
167-170 175-178
off off
3
on on on
175-178
Not supported Not supported
off off off
05
0
on on on on
121-124
121-124 129-132
off off
1
on on on
129-132
129-132 137-140
off off off
2
on on on
137-140
137-140 145-148
off off off
3
on on
145-148
Not supported Not supported
off off off off
06
0
on on on on on
91-94
91-94 99-102
off
1
on on on on
99-102
99-102 107-110
off off
2
on on on on
107-110
107-110 115-118
off off
3
on on on
115-118
Not supported Not supported
off off off