Icom IC-7700 Stereo Amplifier User Manual


 
5-3
DD
Fixed mode
Displays signals within the specified frequency range.
The selected frequency band conditions can be ob-
served at a glance when using this mode.
q Push several times to close a multi-func-
tion screen, if necessary.
w Push [F-1•SCOPE] to select the scope screen.
e Push [F-5•CENT/FIX] to select the fixed mode.
•“ ” is displayed when fixed mode is selected.
r Push [F-2•ATT] several times to activate an attenu-
ator or turn the attenuator OFF.
10, 20 and 30 dB attenuators are available.
Push and hold [F-2•ATT] for 1 sec. to turn OFF the at-
tenuator.
t Push [F-3•MARKER] several times to select the
marker for transmit frequency or turn the marker
OFF.
•“ ” displays the marker at the receive frequency. (al-
ways displayed)
•“ ” displays the marker at the transmit frequency.
• “<<” or “>>” appears when the marker is out of range.
The spectrum scope shows the transmit signal wave-
form while transmitting. This can be deactivated in
scope set mode. (p. 5-5)
The spectrum scope shows the peak level holding func-
tion. Peak levels are displayed in the background of the
current spectrum in a different color until the receive fre-
quency changes. This can be deactivated and the wave-
form color can be set in scope set mode. (p. 5-5)
y Push [F-4•HOLD] to freeze the current spectrum
waveform.
•“ ” appears while the function is in use.
The peak hold function can be deactivated in scope set
mode.
u Push to exit the scope screen.
NOTE: If a strong signal is received, a ghost wave-
form may appear. Push [F-2•ATT] several times to
activate the spectrum scope attenuator in this case.
The scope bandwidth can be specified for each op-
erating frequency band independently in scope set
mode. (pgs. 5-6 to 5-8)
EXIT/SET
HOLD
T
R
FIX
EXIT/SET
F-4
HOLD
F-5
CENT/FIX
EXIT/SET
F-2
ATT
F-3
MARKER
5
FUNCTIONS FOR RECEIVE