6. Lamp & lamp house
6.4 Installation of the xenon bulb lamp
WARNING: DO NOT PERMIT UNAUTHORIZED PERSONNEL TO PERFORM OR ATTEMPT ANY PHASE OF
XENON BULB LAMP HANDLING OR SERVICE.
WARNING: This procedure may only be performed by qualified technical service personnel.
CAUTION: Xenon compact arc lamps are highly pressurized. When ignited, the normal operating temperature
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer’s instructions. The bulb is stable at room temperature, but may still explode if dropped
or otherwise mishandled. Whenever the lamp house, containing a xenon bulb lamp, has to be dismantled or
whenever the protective container or cloth has to be removed from the xenon bulb lamp, authorized protective
clothing MUST be worn!
WARNING: Always wear face protection (full face shield with neck protector) when handling xenon bulb
lamps.
WARNING: Always wear protective clothing (welder’s jacket) when handling xenon bulb lamps.
WARNING: Always wear clean leather gloves with wrist protectors when handling xenon bulb lamps.
The DP-1500 projector is delivered without xenon bulb lamp installed. This procedure also assumes that the
lamp house is closed and that there is no xenon bulb lamp installed inside the lamp house.
Necessary tools
• 17 mm open ended wrench.
• Torque wrench with 17 mm hexagon socket
• Torque wrench with 5 mm Allen socket.
Necessary parts
• Lamp cathode adapter.
• Hexagon socket head screw M6 x 40.
• Plane washer.
How to install the xenon bulb lamp into the lamp house?
1. Ensure that you wear protective clothing, a full face shield and protective gloves.
2. Remove the UV block er and s ide cover of the lamp house by releas ing the retaining thumbscrews as illustrated.
Note: In case of a lamp replacement, the UV blocker will be already removed.
52 R59770091 DP-1500 06/01/2009