6. Lamp & lamp house
6.1 Introduction
Lamp & lamp house
The lamp house of the DP-1500 pro jector is delivered without lamp. The xenon bulb lamp is delivered s eparately and has to be
installed on site by a qualified service technician.
BA
Image 6-1
A Lam p house.
B X enon b ulb lamp.
The xenon bulb lamp is packed in a p rotective container or wrapped in a protective cloth. Never rem ove this protective container or
protective cloth without wearing adequate protective c lothing (face shield, clean cotton glovers, w elder ’s jacket).
Image 6-2
Left: Xenon bulb lamp in protective container. Right: Xenon bulb lamp wrapped in protective cloth.
CAUTION: Xenon compact arc lamps are highly pressurized. When ignited, the normal operating temperature
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer’s instructions. The bulb is stable at room temperature, but may still explode if dropped
or otherwise mishandled. Whenever the lamp house, containing a xenon bulb lamp, has to be dismantled or
whenever the protective container or cloth has to be removed from the xenon bulb lamp, authorized protective
clothing MUST be worn!
Available lamps (without lamp house)
Lamp Type
Order info
Osram xenon bulb lamp of 3 kW
3kW DHP R9855938
Osram xenon bulb lamp of 2 kW
2kW DHP R9855956
Ushio xenon bulb lamp of 3 kW
DXL30BAF R9855940
Ushio xenon bulb lamp of 2 kW
DXL20BAF R9855955
46 R59770091 DP-1500 06/01/2009