Runco SC-30d Home Theater System User Manual


 
External Control
Runco SC-30d/SC-35d Installation/Operation Manual 109
PRE
L
IMINAR
Y
ConstantContrast
(SC-30d only)
CCT R/W No 0 4 No 0 = Off
1 = On
2 = Low
3 = Medium
4 = High
CEC Enable CEC R/W No 0 1 No 0 = Off; 1 = On
Chroma Delay CHR R/WYes07No
Color Gamut CLG R/WYes06No0 = Auto
1 = REC709
2 = SMPTE C
3 = EBU
4 = Native
6 = PCE
Color Offset CLO R/W Yes -50 50 No Picture menu
Color CLR R/W Yes -50 50 No Calibration -> Input Image menu
Color Space CLS R/W No 0 4 No 0 = REC601
1 = REC709
2 = RGB
3 = RGB Video
4 = Auto
Image Alignment Center x CNX R/W Yes -100 100 No
Image Alignment Center y CNY R/W Yes -100 100 No
Contrast CON R/W Yes -50 50 No Calibration -> Input Image menu
Contrast Offset COO R/W Yes -50 50 No Picture menu
Color Temp Simple CTS R/W No 0 4 No 1 = 5500K
2 = 6500K
3 = 7500K
4 = 9300K
CUE CUE R/W No 0 1 No 0 = Off; 1 = On
Display Blue Gain DBG R/W Yes -100 100 No
Display Blue Offset DBO R/W Yes -100 100 No
Default Gateway Byte 1 DE1 R/W Yes 0 255 No
Default Gateway Byte 2 DE2 R/W Yes 0 255 No
Default Gateway Byte 3 DE3 R/W Yes 0 255 No
Default Gateway Byte 4 DE4 R/W Yes 0 255 No
DisplayPort EDID Extension DEE R/W No 0 1 No 0 = Off; 1 = On
Table 6-1. Serial Commands (continued)
Setting
Command
Code
Read/
Write
Inc/
Dec
Min
Value
Max
Value
String? Notes