MGC WebCommander User’s Guide
10-31
5. Define the Advanced parameters as described in Table 10-4.
Table 10-4: Advanced Conference Parameters
Option Description
Auto Termination Select this check box to automatically terminate the
conference by the MCU when:
• No participant has connected to the conference
during a predefined time period
Or
• All participants have disconnected from the
conference and the conference is idle for a
predefined time period
Note:
Make sure that the Auto Terminate parameters are
set when defining a Meeting Room.
Minutes Before
First Join
This option is enabled when the Auto Termination
option is selected.
Enter the number of minutes that should pass from
the time the conference starts without any participant
connecting to the conference, before the conference
is considered as idle. If no participant has joined the
conference during this period, it will automatically be
terminated by the MCU.
Minutes After Last
Quit
This option is enabled when the Auto Termination
option is selected.
Enter the number of minutes that should pass from
the time the last participant disconnects from the
conference, before the conference is considered as
idle. If the conference remains idle and no other
participant joins in during this period, the conference
will be automatically terminated by the MCU.
Dial-Out Manually Select this check box to designate an operator-
controlled dial-out conference connection. If Dial-Out
Manually is checked, the operator or meeting
organizer must connect each of the dial-out
participants.