Extron electronic DVS 605 Stereo System User Manual


 
Command ASCII (Telnet)
(host to processor)
URL Encoded (Web)
(host to processor)
Response
(processor to host)
Additional Description
Re-map port designations
Set Telnet port map
24
E{port #}MT}
W{port #}MT
|
Pmt{port #}
]
Reset Telnet port map
24
E23MT}
W23MT
|
Pmt00023
]
Set Telnet to the default port (23)
Disable Telnet port map
24
E0MT}
W0MT
|
Pmt00000
]
Read Telnet port map
EMT}
WMT
|
{port #}
]
Set web port map
24
E{port #}MH}
W{port #}MH
|
Pmh{port #}
]
Reset web port map
24
E80MH}
W80MH
|
Pmh00080
]
Disable web port map
24
E0MH}
W0MH
|
Pmh00000
]
Read web port map
24
EMH}
WMH
|
{port #}
]
Set web port to default value of 80
Directory commands
Change/create directory
E{path}/{directory}/CJ}
W {path}/{directory}/CJ|
Dir•{path}/{directory}/
]
NOTE: A directory does not actually exist until a file has been copied into the path.
Move back to root directory
E / CJ}
W%2FCJ|
Dir•/
]
Move up one directory
E ..CJ}
W%2E%2ECJ| Dir•{path}/
{directory}/
]
View current directory
E CJ}
WCJ|
{path}/{directory}/
]
File erase commands
Erase user-supplied
file
24, 28
E {filename} EF}
W {filename} EF|
Del • {lename}
]
Erase current directory and
its files
24, 28
E/EF}
W%2FEF|
Ddl
]
Erase current directory and
subdirectories
24, 28
E//EF}
W%2F%2FEF|
Ddl
]
DVS 605 • SIS Communication and Control 60