Extron electronic DVS 605 Stereo System User Manual


 
Command ASCII Command
(host to scaler)
Response
(scaler to host)
Additional Description
Hardwired IR port
Enable IR port
(allows IR)
65*0# IRDisable0]
Enables the hard wired port and allows IR
control input.
Disable IR port
(blocks IR)
65*1# IRDisable1]
Disables the hard wired port (default).
View IR setting
65#
X(]
View the current IR Disable setting.
Picture In Picture
NOTE: HDMI input 5 cannot be used for PIP.
PIP on/off
PIP on
EX2&PIP} PipX2&]
Turn on PIP and display input X2&. X2& is a
two digit response (for example, 01).
PIP off
E0PIP} Pip00]
Turn PIP off.
View PIP selection
EPIP}
X2&]
View PIP selection (X2& is a two digit
response, for example, 01).
Swap main/PIP windows
Swap
% Tke]
Swap between main and PIP window.
On-Screen Menu time-out
NOTE: Setting the time-out to 501 disables the OSD time-out (never times out). Setting the time-out to 0 disables the OSD.
Set menu time-out
EX2%MDUR} MdurX2%]
Set the OSD to X2% seconds.
View time-out
EMDUR}
X2%]
View time-out settings.
Reset commands
Erase user web
pages and files
24 28
E<filename>EF} Del<filename>]
Erase named files.
Erase current
directory and
files
24 28
E/EF} Ddl]
Erase current directory and its files.
Erase current
directory and
subdirectories
24 28
E//EF} Ddl]
Erase current directory and its
subdirectories.
Erase flash
memory
24
EZFFF} Zpf]
Erase the flash memory.
Reset all device
settings to factory
default settings
24
EZXXX} Zpx]
Retains Ethernet settings
Absolute system
reset
24
EZQQQ} Zpq]
Includes resetting networking to DHCP =
Off, IP = 192.168.254.254 (default address)
Absolute system
reset (but retain IP)
24
EZY} Zpy]
NOTE: This reset EZY is similar to ZQQQ but excludes IP address, subnet mask, gateway addresses, unit name,
DHCP setting, and port mapping (Telnet/web/direct access) in order to maintain communications with device.
Recommended after a firmware update.
NOTE: X( = Enable/disable: 0 = off/disable, 1 = on/enable
X2% = On-screen menu time-out: (default = 3 seconds)/output sync time-out (default = 501 - never)
0 = OSD never displayed/output sync is instantly disabled with no active input,
1 to 500 in 1 second increments, 501 = OSD never times out/output sync never times out
X2& = PIP window input selection: 0 to 4 (0 = off)
DVS 605 • SIS Communication and Control 54