Extron electronic DVS 605 Stereo System User Manual


 
SIS Communication
and Control
The DVS 605 can be configured and controlled via a host computer or other device (such
as a control system) attached to the rear panel RS-232 connector or the LAN port or the
front panel USB port. Control is made using the Extron Simple Instruction Set (SIS) of
commands, or the DVS default web pages.
Commands can be entered using a Telnet application such as the Extron DataViewer,
available at www.extron.com. See the DataViewer Help file for use.
This section describes SIS communication and control. Topics that are covered include:
• Host to Scaler Communications
• Commands and Responses
The scaler uses a protocol of 9600 baud, 1 stop bit, no parity, and no flow control and the
rear panel RS-232 captive screw connector has the pin assignments as shown.
RS-232 / IR
Tx Rx
IR
GG
Host to Scaler Communications
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When the DVS 605 determines that a
command is valid, it executes the command and sends a response to the host device.
All responses from the scaler to the host end with a carriage return and a line feed
(CR/LF = ]), indicating the end of the response character string (one or more characters).
Scaler-initiated Messages
When a local event such as a front panel selection or adjustment takes place, the DVS 605
scaler responds by sending a message to the host. No response is required from the host.
Example scaler-initiated messages are listed here.
• ] © Copyright 2012, Extron Electronics, DVS 605, Vx.xx, 60-1059-
01
] Thur, 17 February 2012 11:27:33 ] The DVS 605 sends the copyright
message when it first powers on. Vx.xx is the firmware version number.
• In X! All ] (where X! is the input number during an input switch).
• Reconfig ] The DVS 605 sends this response when an input is switched or when a
new signal is detected.
Copyright Information
] © Copyright 2012, Extron Electronics, DVS 605, Vx.xx, 60-1059-
01
] Thur, 17 February 2012 11:27:33 ]] © Copyright 2012, Extron
Electronics, DVS 605, Vx.xx, 60-1059-01
] Thur, 17 February 2012
11:27:33
]
The copyright message is displayed upon connecting to an DVS product via TCP/IP or
Telnet. Vx.xx is the firmware version number. The current date and time are displayed.
This is followed by a Password prompt if a password has been set.
DVS 605 • SIS Communication and Control 34