Extron electronic DVS 605 Stereo System User Manual


 
X12% = Connections security level:
0 = anonymous, 11 = user,
1 – 10 = extended security levels 1 thru 10 12 = Administrator
X12& = The number of seconds before timeout on the IP connection: min. = 1; max. = 65000;
(default = 30 = 300 seconds). If no data is received during the timeout period, the
Ethernet connection is closed. Each step = 10 seconds. Applicable only when
connected via Ethernet. When connected via RS-232 only the global timeout
commands apply (current returns E13). Response is returned with leading zeros.
X13! = Firmware Query (‘Q’ commands)
*Q = Firmware and build number [<X.YY.ZZZZ> ]
0Q = Verbose version information [<2Q> - <3Q> - < 4Q>] sum of responses from 2Q-3Q-4Q
1Q = Firmware version [<currently running code (X.YY)>]
2Q = Final stage bootloader (Uboot) version [<X.YY>]
3Q = Factory base code version [<factory base code (X.YY)>*<kernel version (X.YY) –
description – date loaded >]
4Q = Updated firmware version [<updated code version (X.YY)>*<kernel version (X.YY) –
description – date loaded >]
NOTE: For 3Q and 4Q, an asterisk ‘*’ after version number indicates which version is
currently running. A question mark (?.??) indicates that only the factory firmware
version is loaded. A caret (^) indicates the firmware version that should be running,
but a Mode 1 reset was executed and the default factory firmware version is loaded.
An exclamation point (!) indicates corrupted firmware.
[Example: 1.03*(1.42-DVS 605 -Thur, 21 Apr 2012 22:30:57 GMT).]
The SIS Command and Response tables start on the next page.
DVS 605 • SIS Communication and Control 41