Sony DMX-R100 Stereo Amplifier User Manual


 
78
Chapter 3 Menu
Chapter 3 Menu
Menu Windows
A MODE button
B SOURCE button
B MAIN PLL status
Displays the status of PLL which generates clock
signals used internally by the unit.
LOCK: Operating correctly.
UNLOCK: Synchronization is lost. When the word
clock signal is selected as the reference signal, check
the setting of the terminated resistor or if the word
clock selector is set correctly. Check whether the
device that supplies the clock signal is working
correctly.
When INTERNAL or VIDEO is selected as the
reference signal, the unit may be defective.
NO WORD: The word clock signal is not input.
When WORD CLOCK is selected as the reference
signal, check the setting of the terminated resistor or if
the word clock selector is set correctly. Check whether
the device that supplies the clock signal is working
correctly.
When INTERNAL or VIDEO is selected as the
reference signal, the unit may be defective.
4 CHANGE button
Touch this button to change the setting of the SYNC
CLOCK section. A dialog box appears. After
confirming, select [OK]. The unit restarts and the
settings are changed.