Sony DMX-R100 Stereo Amplifier User Manual


 
77
Chapter 3 Menu
Chapter 3 Menu
A INTERNAL button
B VIDEO button
C WORD/DI button
D Word clock selector
A VIDEO PLL status
B MAIN PLL status
The maximum value of the programmable delay
amount is half.
The channel number of the EXT inputs of
MONITOR is reduced from 6 to 2.
When INPUT is selected in the CHANNEL
METERS section in the MISC SETUP window, the
OVER indicator does not function.
The SOLO buttons of the AUX Return function as
AFL buttons even if these are set to PFL.
When SYNC LOCK is set to WORD/DI, if the sync
reference signal is greater than 96 kHz, the DSP
(Digital Signal Processor) does not work properly
and this may cause noise.
2 SYNC CLOCK section
The unit synchronizes using the reference selected by
touching one of these buttons.
A INTERNAL button
Touch this button to use the built-in word clock
generator as the reference signal.
When this button is selected, external digital audio
equipment must be synchronized with the DMX-R100
that is the sync master.
B VIDEO button
The unit synchronizes using the video signal connected
to the REF VIDEO connector on the unit. When this
button is selected, external digital audio equipment
must be synchronized either to the same video signal
or to a synchronous word clock, as produced by the
mixer.
C WORD/DI (digital input) button
The unit synchronizes using a word clock signal
connected to the REF WORD connector or a digital
audio signal connected to any of the mixer digital
inputs. You can select which signal you use as the
reference signal by using the word clock selector D.
When this button is selected, the unit and external
digital audio equipment must be synchronized using
the same reference sync signal.
D Word clock selector
Displays the source of the external reference word
clock when the WORD/DI button C is touched.
Touching the selector results in opening the list and
you can then select the source from the following.
REF WORD IN
2TR IN 2
AUX RTN 5/6, 7/8
CH 1/2, CH3/4, CH5/8 or CH7/8 for SLOT 1 to
SLOT 4
3 PLL status display section
A VIDEO PLL status
When the VIDEO is selected as the reference signal,
the status of PLL which generates the word clock
signal from the video signal is displayed.
When a signal other than VIDEO is used as the
reference signal, “– –” is displayed.
LOCK: Operating correctly.
UNLOCK: Synchronization is lost. Check the setting
of the terminated resistor or whether the correct video
signal is being inputted.
NO VIDEO: The video signal is not input. Check the
setting of the terminated resistor or whether the correct
video signal is inputted.
: A signal other than VIDEO is used.