Fujitsu RX100 S2 Stereo System User Manual


 
210
Chapter 8 Hardware Configuration/Utilities
Mode Continue (at the time of
purchase)
Reset
Power Cycle
Sets the operation to be performed when a timeout
occurs during OS boot monitoring.
Continue: The boot sequence is continued.
Reset: The server restarts automatically and
starts POST.
Power Cycle: The server turns off automatically.
The server turns on automatically after the time
specified in [Power cycle Delay].
Timeout Value 0 (at the time of
purchase)
1–100
When [O/S Boot Timeout] is set to [Enabled], the
system restarts automatically if the OS fails to start
up within the time set for this item.
ASR&R Boot Delay (min) 2 (at the time of
purchase)
1–30
Sets the standby time for startup after shutdown due
to trouble (such as overheating) in minutes. The
system restarts after the set standby time.
Power Cycle Delay 10 (Fixed parameter) Sets the time until the server is turned on after it is
turned off.
Boot Retry Counter 0
•1
•2
3 (at the time of
purchase)
•4
•5
•6
•7
Sets the maximum number of attempts to boot the
OS within the range of 0 to 7.
Diagnostic System Disabled (Fixed parameter) Sets the operation to be performed when the
number of system boot retries exceeds the number
specified in [Boot Retry Counter].
Next Boot uses Boot Option (Fixed
parameter)
Specifies how to boot the system at the next startup.
This value can be selected when [Diagnostic
System] is set to [LAN] or [Remote Image Disk].
Diagnostic PXE boot
device
0 (Fixed parameter) The server does not support this.
Critical Temperature
Monitoring
Disabled (at the time of
purchase)
Enabled
Sets whether or not to turn the power off in the
event of abnormal temperature.
Clear Screen Delay (sec) 5 (at the time of
purchase)
0–31
Sets the time (seconds) during which the last BIOS
message screen is displayed before the OS starts up.
IPMI [Enter] Configures the Baseboard Management Controller
(BMC).
"8.2.12 IPMI Submenu" (pg.211)
CPU Status [Enter] Displays whether or not to allow the use of the
installed CPU.
"8.2.13 CPU Status Submenu" (pg.212)
Memory Status [Enter] Sets whether or not to allow the use of the installed
memory.
"8.2.14 Memory Status Submenu" (pg.213)
Console Redirection [Enter] Configures detailed settings for console redirection.
"8.2.15 Console Redirection Submenu" (pg.214)
table: Items on the Server Menu
Item Setting Description