Command ASCII Command
(host to scaler)
Response
(scaler to host)
Additional Description
Advanced Conguration
Test pattern
Set test pattern
EX2)TEST} TestX2)]
Set the test pattern to X2).
View test pattern
ETEST}
X2)]
View the current test pattern.
Freeze
Enable
1F Frz1]
Freeze selected input.
Disable
0F Frz0]
Unfreeze selected input.
View
F
X(]
Show the freeze status (1= on, 0= off).
Auto memories (per input)
Enable
EX!*1AMEM} AmemX!*1]
Set auto memory on. Previous settings for
incoming signal are auto recalled.
Disable
EX!*0AMEM} AmemX!*0]
Set auto memory off. Manual recall of
input presets needed to configure input.
View setting
EX!AMEM}
X(]
View current auto memory for input X!.
Input aspect ratio (per input)
Enable Fill mode
EX!*1ASPR} AsprX!*1]
Sets input X! to always fill the entire raster
(default).
Enable Follow
mode
EX!*2ASPR} AsprX!*2]
Sets input X! to preserve its native aspect.
View aspect setting
EX!ASPR}
X2(]
View aspect ratio setting for input X!.
Auto switch mode
Disable
E0AUSW} Ausw0]
Manual switching only (default).
Priority to highest
active
E1AUSW} Ausw1]
Gives priority to the highest numbered
active input.
Priority to lowest
active
E2AUSW} Ausw2]
Gives priority to the lowest numbered
active input.
View setting
EAUSW}
X3&]
View the current auto switch mode.
Video effect
Cut
E0SWEF
}
Swef0]
Sets the switch to cut.
Dissolve
E1SWEF} Swef1]
Sets the switch to dissolve.
View setting
ESWEF} 0] (or 1])
View setting (0 = cut, 1 = dissolve).
NOTE: X! = Input selection: 1 to 5
X( = Enable/Disable: 0 = Off/disable, 1 = On/enable
X2) = Test patterns:
0 = off (default) 4 = crosshatch 8 = ramp 12 = 1.85 aspect ratio
1 = crop 5 = 4x4 crosshatch 9 = white eld 13 = 2.35 aspect ratio
2 = alternating pixels 6 = color bars 10 = 1.33 aspect ratio 14 = blue mode
3 = alternating lines 7 = grayscale 11 = 1.78 aspect ratio
X2( = Aspect ratio:
1 = Fill; each input rate will automatically fill the entire output raster (default)
2 = Follow; each input rate will be displayed with its native aspect ratio
X3& = Auto switch mode: 0 = Disable (default),1 = Priority to highest numbered input, 2 = Priority to lowest numbered input
DVS 605 • SIS Communication and Control 44