Extron electronic DVS 605 Stereo System User Manual


 
SIS Communication
and Control
The DVS 605 can be congured and controlled via a host computer or other device (such
as a control system) attached to the rear panel RS-232 connector or the LAN port or the
front panel USB port. Control is made using the Extron Simple Instruction Set (SIS) of
commands, or the DVS 605 Conguration Software Program, or the DVS default web
pages.
Commands can be entered using a Telnet application such as the Extron DataViewer,
available at www.extron.com. See the DataViewer Help le for use.
This section describes SIS communication and control. Topics that are covered include:
Host to Scaler Communications
Commands and Responses
The scaler uses a protocol of 9600 baud, 1 stop bit, no parity, and no ow
control and the rear panel RS-232 captive screw connector has the pin
assignments as shown.
RS-232 / IR
Tx Rx
IR
GG
Host to Scaler Communications
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When the DVS 605 determines that a
command is valid, it executes the command and sends a response to the host device.
All responses from the scaler to the host end with a carriage return and a line feed
(CR/LF = ]), indicating the end of the response character string (one or more characters).
Scaler-initiated Messages
When a local event such as a front panel selection or adjustment takes place, the DVS 605
scaler responds by sending a message to the host. No response is required from the host.
Example scaler-initiated messages are listed here.
] © Copyright 2012, Extron Electronics, DVS 605, Vx.xx, 60-1059-
01
] Thur, 17 February 2012 11:27:33 ] The DVS 605 sends the copyright
message when it rst powers on. Vx.xx is the rmware version number.
In X! All ] (where X! is the input number during an input switch).
Reconfig ] The DVS 605 sends this response when an input is switched or when a
new signal is detected.
Copyright Information
] © Copyright 2012, Extron Electronics, DVS 605, Vx.xx, Fri, 17 Feb
2012 11:27:33
]
The copyright message is displayed upon connecting to an DVS product via TCP/IP or
Telnet. Vx.xx is the rmware version number. The current date and time are displayed.
This is followed by a Password prompt if a password has been set.
DVS 605 • SIS Communication and Control 27