Sony PDW-R1 CD Player User Manual


 
Chapter 7 Menus
112
7-4 Maintenance Menu
7-4 Maintenance Menu
7-4-1 Items in the Maintenance Menu
The following tables show the items in the maintenance
menu.
Item names are the names which appear in the video
panel, and on an external monitor to which the output of
the VIDEO OUT 2 (SUPER)/SDI OUT (SUPER)
connector is input.
The values in the Settings columns are the values which
appear in the time data display section. (The values may
appear in a different format in the video panel and on an
external monitor. In this case, the video panel values are
shown in parentheses.) Underlined values are the factory
defaults.
For information about the DRIVE MAINTENANCE,
ADJUST, CHECK, BATTERY CONFIG and SERVICE
SUPPORT items, refer to the Maintenance Manual.
AUDIO CONFIG: items relating to audio control
Item Setting
METR HEAD ROOM Select the audio reference level (headroom).
–12dB,–16dB, –18dB, –20dB
(525(U)/525(J) line modes)
–12dB, –16dB, –18dB, –20dB
, EBUL (625 line mode)
DATA LENGTH When “IMX50,” “IMX40,” or “IMX30” is selected in setup menu item 031, this selects the
audio quantization bit count and number of recording channels.
16
×
8 (16bit
×
8ch): 16 bits × 8 channels
24×4 (24bit × 4ch): 24 bits × 4 channels
Note
When item 031 is set to “DVCAM,” the setting is automatically fixed at 16 bits × 4 channels.
NON-AUDIO INPUT Select whether to handle digital audio signals as non-audio signals during recording.
Audio (audio)
: Handle as audio signals.
data: Handle as non-audio signals.
Sub-item
tr1/tr2
tr3/tr4
tr5/tr6
tr7/tr8
INPUT LEVEL Set the upper limit for the signal level input to audio channels 1/3 or 2/4.
+4dB
, 0dB, –3dB, –6dB (525(U)/525(J) line modes)
+4dB
, 0dB, –3dB, –6dB, EBUL (625 line mode)
Sub-item
CH1/CH3
CH2/CH4
OUTPUT LEVEL Set the reference level for audio output signals.
+4dB
, 0dB, –3dB, –6dB (525(U)/525(J) line modes)
+4dB
, 0dB, –3dB, –6dB, EBUL (625 line mode)
NETWORK CONFIG: items relating to network settings
Item Setting
DHCP Set whether to assign an IP address automatically with the DHCP server.
DISABLE
: Do not assign automatically.
ENABLE: Assign automatically.
IP ADDRESS PRESET Set IP address.
192.168.001.010
Note