Symptom Cause and countermeasure
The sound skips.
Play does not start
from the first
track.
Recording or
editing was done,
but the TOC is not
updated.
Play does not finish
even when Repeat
Play is not selected.
Or the MD deck goes
back to the first track
during Shuffle or
Program Play.
Recording is not
possible.
The system is subject to vibration.
m Try moving the system to a place without vibration (e.g., on top of a stable
stand).
m Try moving the speakers away from the system, or placing them on separate
stands.
When you listen to a track with bass sounds at high volume, the speaker
vibration may cause the sound to skip.
The inside of the system and the disc are different temperatures.
m Insert the disc and wait for 10 to 20 minutes with the system turned on.
The MD deck is in Program or Shuffle Play mode.
m Press PLAY MODE repeatedly until “PROGRAM” or “SHUFFLE” disappears
to return to normal play.
You pulled out the power cord without ejecting the MD after recording or
editing an MD.
m MD recording and editing contents are written to the MD when the MD is
ejected, so make sure you eject the MD after recording or editing (see pages 35
and 50).
The MD could not be read properly, or it is not inserted completely.
m Remove the MD and then reinsert it to the correct position (until it stops).
The MD is protected against erasure (“C11” and “Protected” appear alternately).
m Eject the disc and slide the tab closed to cover the hole (see page 35).
The optional A/V component is not connected properly.
m Connect the optional A/V component properly (see page 75, 78 and 79).
The sound source is set to MD.
m Switch to another sound source.
A premastered MD is inserted in the deck.
m Replace the MD with a recordable MD.
There is no time remaining on the MD.
m Replace the disc with a recordable MD, or use the Erase Function to erase
unnecessary tracks (see pages 53 – 56).
The CD disc tray is open.
m Press 6 to close the tray.
The power cord was unplugged or a power interruption occurred during
recording.
m Start recording over from the beginning.