ClearOne comm XAP 400 Stereo System User Manual


 
75
Operation ~ Utilities
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Auto Sweep provides the ability to move the frequency of the tone generator
from a low frequency to a high frequency at a specified rate. Click Auto
Sweep to begin the frequency sweep. The Frequency slide control and readout
reflect the progress of the Auto Sweep. Auto Sweep stops at the last frequency
in the sweep range upon completion of the sweep. Or you can click the button
at any time to stop the sweep. Sweep range is 20Hz—20kHz; increment range
is 10Hz—20kHz, and the rate range is 10ms—2000ms. Default is 100ms.
Select
Repeat
if you want Auto Sweep to continue in cycles.
4. Click Signal On to generate the tone. Click Signal On again to terminate
the noise signal.
Document Compare Utility
The Document Compare Utility samples and compares configuration information
between two sites. These can exist as actual sites/units or as documents (site files)
that are saved to your computer. It shows you where differences are between the two
and allows you to copy and paste settings between them. Open the Compare Utility
by clicking on the Compare Utility toolbar button.
Figure 5.6. Document Compare Utility showing two XAP 400 sites. The items
listed in the Site 1 and Site 2 columns show where the differences are found.
Figure 5.4. Compare Utility button
Figure 5.5. You can also open the Document
Compare Utility from the Start menu