ClearOne comm XAP 400 Stereo System User Manual


 
17
Installation ~ LCD Programming
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Inputs
Select which input (1–4) you want to monitor on the LCD and LED display. Scroll to
the input, then press Enter. The meter displayed is the post-gain meter.
Outputs
This submenu allows you to choose which output (1–8) you want to monitor on the
LCD and LED display. Scroll to the output you want to monitor, then press Enter.
Processing
This submenu allows you to choose which processing channel (A-D) you want to
monitor on the LCD and LED display. Scroll to the output you want to monitor, then
press Enter.
ERL
This submenu allows monitoring of the ERL meters on the XAP 400. Select the
meter you want to monitor and press Enter.
ERLE
This submenu allows monitoring of the ERLE meters on the XAP 400. Select the
meter you want to monitor and press Enter.
Telco RX
This submenu allows you to monitor the Telco RX (Receive) meter on the XAP 400.
Press Enter to enable your selection.
Telco TX
This submenu allows you to monitor the Telco TX (Transmit) meter on the XAP 400.
Press Enter to enable your selection.
TERL
This submenu allows you to monitor the TERL meter on the XAP 400. Press Enter
to enable your selection.