Appendices ~ Appendix E: Serial Commands
118
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
FMP - First Mic Priority Mode
This command selects/reports first Mic priority mode for a gating group.
Command form: DEVICE
FMP
<Channel> [Value]
Argument details
Name Description
Device 0–7 or * to select all units
FMP Command form
Channel 1–4 (selects mic inputs), A–D (selects gating group)
Value 0 = Off, 1 = On, 2 = Toggle, Null returns the current mode
Example:
#75 FMP A 1
On XAP 400 unit 5 (
#75
), the first mic priority mode
(
FMP
) for gating group
A
is set to on (
1
).
FPP - Front Panel Passcode
This command sets and reports the current passcode setting for the unit. Each
character in the password represents a button on the front panel. See button
assignment table below. When the user is requested to unlock the front panel, they
must press the buttons in the sequence of the stored password.
Command form: DEVICE
FPP
<char1><char2><char3><char4><char5>
Button assignment
Value Button represented
1 Up arrow button
2 Enter button
3 ESC button
4 Down arrow button
5 Meter button
Argument details
Name Description
Device 0–7 or * to select all units
FPP Command form
Char 1–5 1–5 (see button assignments)
CLEAR will clear the passcode
Null will return current passcode
Example:
#75 FPP 12345
On XAP 400 unit 5 (
#75
), the front panel passcode
(
FPP
) is set to Up Arrow (
1
), Enter (
2
), Esc (
3
), Down Arrow (
4
), Meter (
5
).