ClearOne comm XAP 400 Stereo System User Manual


 
125
Appendices ~ Appendix E: Serial Commands
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
LVLREPORT - Level Report
This command selects level status reporting.
Command form: DEVICE
LVLREPORT
<Channel> <Group> [Position] [Value]
Argument details
Name Description
Device 0–7 or * to select all units
LVLREPORT Command form
Channel See Groups and Channels, page 103
Group See Groups and Channels, page 103
Position See Meter Type Definitions, page 104
Value 0 = Off (Delete level from list of levels to be reported)
1 =On (Add specified level to list of levels to be reported)
2 = Toggle
Example:
#72 LVLREPORT 8 L I 1
On XAP 400 unit 2 (
#72
), the level
(
LVLREPORT
) of line level (
L
) input
8
at the input stage (
I
) is to be added (
1
) to
the report.
LVLRRATE - Level Report Rate
Sets the level report rate for the unit and activates/deactivates level repeating.
Command form: DEVICE
LVLRRATE
[Value]
Argument details
Name Description Units
Device 0–7 or * to select all units
LVLRRATE Command form
Value 0 = Turn off reporting but leave current list
1 = Turn off reporting and clear the list
50 to 1000 = Set Rate (1 meter every x ms) ms
Null to return current value
Example:
#73 LVLRRATE 100
On XAP 400 unit 3 (
#73
), the level report rate
(
LVLRRATE
) is set to
100
ms.