Appendices ~ Appendix E: Serial Commands
140
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
SIGTOUT - Signal Generator Time Out
Sets the signal generator time out for the unit.
Command form: DEVICE
SIGTOUT
[Value]
Argument details
Name Description
Device 0–7 or * to select all units
SIGGEN Command
Value 0 = Off, 1–30 = Set time out minutes, Null = Current rate
Example:
#57 SIGTOUT 15
On XAP 400 unit 7 (
#77
), the signal generator
time out (
SIGTOUT
) is set to
15
minutes.
SLVL - Speech Level Control Enable/Disable
This command selects/reports the setting of speech level control for a microphone.
Command form: DEVICE SLVL <Channel> [Value]
Argument details
Name Description
Device 0–7 or * to select all units
SLVL Command
Channel 1–4 (select mic input)
Value 0 = Off, 1 = On, 2 = Toggle, Null = Current mode
Example:
#70 SLVL 2 M 1
On XAp 400 unit 0 (
#70
), the speech leveler for
mic (
M
) channel
2
is set to on (
1
).
SPEEDDIAL - Speed Dialing
This command dials a speed dial number.
Command form: DEVICE
SPEEDDIAL
<Channel> [Value]
Argument details
Name Description
Device 0–7 or * to select all units
SPEEDDIAL Command
Channel See Groups and Channels, page 103
Value 1 – 10, Null to query in text
Example:
#71 SPEEDDIAL 15
On XAP 400 unit 1 (
#71
),
SPEEDDIAL
the
hybrid (
1
) with the number stored in location
5
.