ClearOne comm XAP 400 Stereo System User Manual


 
Appendices ~ Appendix C: Control Panel
100
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
6. Connect one connector terminator block to the Remote Panel on the
XAP/PSR unit. Route the other end of the cable through the back of the
electrical wall box and connect the terminator block to the Control Panel.
7. To use a second Control Panel, connect it to the unused Remote Panel
connector on the XAP/PSR unit or the unused connector on the first Control
Panel. You can daisy-chain up to six Control Panels to each Remote Panel
connector. Total cable run depends on the number of Control Panels used.
The distance information in the table at left is based on Cat. 5 cable with a
nominal resistance of 27 per 1,000 feet (305 meters). All distances refer
to total cable runs from a single Remote Panel connector. For information
about extending beyond 800 feet (244 meters) total with six Control Panels,
call Technical Support at 1-800-283-5936.
8. As shown in Figures C.5 and C.6, use the supplied pan-head screws to install
the Control Panel PCB assembly to the electrical wall box.
9. To install the facia plate, position it over the conductive rubber switch pads
on the PCB assembly, as shown in Figures C.5 and C.6.
10. Mount the faceplate over the rubber switch pads, using the two flat HD
screws.
# of Control Panels Maximum Distance
1 3,000 ft/914 m
2 2,500 ft/762 m
3 1,600 ft/488 m
4 1,200 ft/366 m
5 1,000 ft/305 m
6 800 ft/244 m
Figure C.4. Control panel distance chart
Control Panel Assembly
Dimensions (both versions):
1.8˝/4.6cm W x 4.125˝
/10.5cm L (not including faceplate
or electrical box).
915-155-050 ASSEMBLY, SELECT CONTROL PANEL INCLUDES:
820-155-050 CONTROL PANEL PCB ASSEMBLY W/TWO FOUR-PIN PHOENIX CONNECTORS
740-155-052 CONTROL PANEL MOUNTING BRACKET
625-100-006 ELASTOMER CONDUCTIVE RUBBER SWITCH PADS (4 EACH)
SELECT CONTROL PANEL 910-155-050
460-155-002 WALL ENCLOSURE 2.25 X 3.25 INCHES
681-010-616 SCREWS (2) 6-32 X 1 INCH PPH
740-155-050 FACIA PLATE
460-155-001 FACEPLATE
FLAT HEAD SCREWS (2)
INCLUDED WITH FACEPLATE
673-016-104
CONN TERM BLOCK/
F EURO 4 P
(2 EACH)
Figure C.5. Select Control Panel Assembly