113
Appendices ~ Appendix E: Serial Commands
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
COUNTRY – Country Selection
This command sets/reports the country for compliance.
Command form: DEVICE
COUNTRY
[Value]
Argument details
Name Description
Device 0–7 or * to select all units
COUNTRY Command form
Value 1 = US / Canada, 2 = Europe (CTR21), 3 = Mexico
4 = Australia, 5 = South Africa, 6 = Japan
7 = Brazil, Null to return current state
Example:
#70 COUNTRY 1
On the XAP 400 unit 0 (
#70
), the country selection
(
COUNTRY
) is set to US/Canada (
1
).
DECAY - Decay Adjust
This command selects/reports the setting of the decay rate for a specified input.
Command form: DEVICE
DECAY
<Channel> [Value]
Argument details
Name Description
Device 0–7 or * to select all units
DECAY Command form
Channel Range 1–4 (selects mic input)
Value 1 = Slow, 2 = Medium, 3 = Fast, Null to return current state
Example:
#73 DECAY 1 3
On XAP 400 unit 3 (
#73
), the decay rate (
DECAY
)
for mic channel
1
is set to fast (
3
).
DELAY - Delay Adjust
This command selects/reports the delay time of each assignable processing channel.
Command form: DEVICE
DELAY
<Channel> [Value]
Argument details
Name Description Units
Device 0–7 or * to select all units
DELAY Command form
Channel A–D (select processing channel)
Value 0.00 to 250 (selects delay) ms
Null to return current state
Example:
#76 DELAY A 200
On XAP 400 unit 6 (
#76
) the delay (
DELAY
) for
processing channel
A
is set to
200
ms.