ClearOne comm XAP 400 Stereo System User Manual


 
143
Appendices ~ Appendix E: Serial Commands
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
TOUT - Time Out Select
This command selects/reports the inactivity time out before returning to the unit title
screen.
Command form: DEVICE
TOUT
[Value]
Argument details
Name Description
Device 0–7 or * to select all units
TOUT Command
Value 0 = Off, 1–15 (select time out in minutes)
Null = Current mode
Example:
#72 TOUT 5
On XAP 400 unit 2 (
#72
), the front panel of the unit will
time out (
TOUT
) after
5
minutes.
UID - Unit ID
This command reports the unit ID. This command is read only.
Command form: DEVICE
UID
[Value]
Argument details
Name Description Units
Device 0–7 or * to select all units
UID Command
Value Null to return value Hexadecimal
Example:
#73 UID B465F991
The unit ID number (
UID
) received from XAP 400
unit 3 (
#73
), is
B456F991
.
VER - Version
This command reports the firmware version of the unit. This command is read only.
Command form: DEVICE
VER
[Value]
Argument details
Name Description
Device 0–7 or * to select all units
VER Command
Value Null to return value
Example:
#74 VER 1.0.0
The version of the firmware (
VER
) programmed into
XAP 400 unit 4 (
#74
), is
1.0.0
.