ClearOne comm XAP 400 Stereo System User Manual


 
121
Appendices ~ Appendix E: Serial Commands
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
GRATIO - Gate Ratio Adjust
This command selects/reports the setting of the gate ratio.
Command form: DEVICE
GRATIO
<Channel> [Value]
Argument details
Name Description Units
Device 0–7 or * to select all units
GRATIO Command form
Channel 1–4 (select mic input)
Value 0 to 50 dB
Null to return current ratio
Example:
#72 GRATIO 1 15
On XAP 400 unit 2 (
#72
), the gate ratio
(
GRATIO
) for mic channel
1
is set to
15
dB.
GREPORT - Gate Report
This command selects/reports the gate status.
Command form: DEVICE
GREPORT
<Value>
Argument details
Name Description
Device 0–7 or * to select all units
GREPORT Command form
Value 0 = Off, 1 = On, 2 = Toggle
Example:
#73 GREPORT 1
On XAP 400 unit 3 (
#73
), the gate reporting
(
GREPORT
) is set to on (
1
).
GRPSEL - Gating Group Select
This command selects/reports which gating group each input is assigned. There can
only be one selection per input.
Command form: DEVICE
GRPSEL
<Channel> [Value]
Argument details
Name Description
Device 0–7 or * to select all units
GRPSEL Command form
Channel 1–4 (selects mic input)
Value A–D (selects gating group), Null to return current value
Example:
#74 GRPSEL 1 A
On XAP 400 unit 4 (
#74
), mic channel
1
is
assigned to gating group (
GRPSEL
)
A
.
Gate report sends a report
on every gate change. If no
mics are gated on, the
report will be sent every 10 seconds.