ClearOne comm XAP 400 Stereo System User Manual


 
117
Appendices ~ Appendix E: Serial Commands
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Examples
#70 FILTER 1 M 3 2 200
On XAP 400 unit 0 (
#70
) the filter (
FILTER
) for mic
(
M
) channel
1
, node
3
is set as a low-pass filter (
2
) at
200
Hz.
#71 FILTER B P 2 4 3000 -10
On XAP 400 unit 1 (
#71
) the filter (
FILTER
) for
processing (
P
) channel
B
, node
2
, is set as a low shelving (
4
) filter at
3000
Hz and a
gain of
-10
dB.
#72 FILTER 3 M 2 6 5000 -15 1.00
On XAP 400 unit 2 (
#72
), the filter
(
FILTER
) for mic (
M
) channel
3
, node
2
, is set as a PEQ (
6
) with a center frequency
of
5000
Hz, a bandwidth of
1.00
, and a gain of
-15
dB.
#73 FILTER B P 2 7 4000
On XAP 400 unit 3 (
#73
), the filter (
FILTER
) for
processing (
P
) channel
B
, node
2
, is set as a CD Horn (
7
) at a frequency of
4000
Hz.
FILTSEL - Filter Select
This command turns on and off the filters on input and audio processing channels.
Command form: DEVICE
FILTSEL
<Channel> <Group> <Node> [Value]
Argument details
Name Description
Device 0–7 or * to select all units
FILTSEL Command form
Channel See Groups and Channels, page 103
Group M = Mic Inputs, P = Processing Channels
Node 1-4, or * for all (selects mic input filter)
1-15, or * for all (selects processing channel filter)
Value 0 = Off, 1 = On, 2 = Toggle, Null to return current state
Example:
#74 FILTSEL B P 2 1
On XAP 400 unit 4 (
#74
), the filter
(
FILTSEL
) on processing (
P
) channel
B
, node
2
, is set to on (
1
).
FLOW - Flow Control
This command selects/reports the flow control of the serial port on the unit.
Hardware flow control is implemented using DTR and DSR.
Command form: DEVICE
FLOW
[Value]
Argument details
Name Description
Device 0–7 or * to select all units
FLOW Command form
Value 0 = Off, 1 = On, 2 = Toggle, Null to return current state
Example:
#76 FLOW 1
On XAP 400 unit 6 (
#76
), the flow control (
FLOW
) to
the RS-232 port is set to on (
1
).