ClearOne comm XAP 400 Stereo System User Manual


 
137
Appendices ~ Appendix E: Serial Commands
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
RINGER - Audible Ring Selection
This command sends/reports the use of an audible ring.
Command form: DEVICE
RINGER
<Channel> [Value]
Argument details
Name Description
Device 0–7 or * to select all units
RINGER Command
Channel See Groups and Channels, page 103
Value 0 = Off, 1 = On, 2 = Toggle, Null = Current state
Example:
#72 RINGER 11
On XAP 400 unit 2 (
#72
), the audible
RINGER
indication for the hybrid (
1
) is on (
1
).
RINGERLVL - Audible Ring Level
This command selects/reports the audible ring level.
Command form: DEVICE
RINGERLVL
<Channel> [Value]
Argument details
Name Description Units
Device 0–7 or * to select all units
RINGERLVL Command
Channel See Groups and Channels, page 103
Value -12.00 – 12.00 dB
(Null to query in text)
Example:
#73 RINGERLVL 13
On XAP 400 unit 3 (
#73
), the audible ringer
level (
RINGERLVL
) for the hybrid (
1
) is
3
dB.
RXBOOST - Receive Boost
This command selects/reports the receive boost status.
Command form: DEVICE
RXBOOST
<Channel> [Value]
Argument details
Name Description Units
Device 0–7 or * to select all units
RXBOOST Command
Channel See Groups and Channels, page 103
Value 0, 3, 6, 9, 12 dB
Null to return current state
Example:
#74 RXBOOST 1 6
On XAP 400 unit 4 (
#74
), the receive boost
(
RXBOOST
) of the hybrid (
1
) is set to
6
dB.