Polycom SIP 3.1 Speaker System User Manual


 
Administrator’s Guide SoundPoint IP / SoundStation IP
A - 86
Basic Logging <level/><change/> and <render/>
This configuration attribute is defined as follows:
Attribute
Permitted
Values Default Interpretation
log.level.change.xxx 0-5 4 Control the logging detail level for
individual components. These are
the input filters into the internal
memory-based log system.
Possible values for xxx are so,
app1, sip, sspsc, ssps, pps, net,
cfg, cdp, pmt, ftp, ares, dns, cxss,
httpd, rdisk, copy, slog, res, key,
log, curl, rtos, mb, ib, sotet, ttrs,
srtp, usb, efk, clink, ldap, and peer,
and pnetm.
log.render.level 0-6 1 Specifies the lowest class of event
that will be rendered to the log files.
This is the output filter from the
internal memory-based log system.
The
log.render.level
maps to
syslog severity as follows:
0 -> SeverityDebug (7)
1 -> SeverityDebug (7)
2 -> SeverityInformational (6)
3 -> SeverityInformational (6)
4 -> SeverityError (3)
5 -> SeverityCritical (2)
6 -> SeverityEmergency (0)
7 -> SeverityNotice (5)
For more information, refer to
Syslog Menu on page 3-11.
log.render.type 0-2 2 Refer to above table for timestamp
type.
log.render.realtime 0, 1 1 Set to 1.
Note: Polycom recommends that
you do not change this value.
log.render.stdout 0, 1 1 Set to 1.
Note: Polycom recommends that
you do not change this value.
log.render.file 0, 1 1 Set to 1.
Note: Polycom recommends that
you do not change this value.