Polycom SIP 3.1 Speaker System User Manual


 
Configuration Files
A - 83
LEDs <led/>
In the following table, x is the LED number.
Graphic Icons <gi/> <IP_300/>, <IP_330>, <IP_400/>, <IP_500/>, <IP_600/>,
<IP_4000/>, and <IP_7000/>
In the following table, x=IP_300, IP_330, IP_400, IP_500, IP_600, IP_4000, or
IP_7000, y is the graphic icon number. Note that IP_300 parameters affect
SoundPoint IP 301 phones, IP_330 parameters affect SoundPoint IP 320 and
330 phones, IP_400 parameters affectSoundPoint IP 430 phones, IP_500
parameters affect SoundPoint IP 501 phones, and IP_600 parameters affect
SoundPoint IP 550, 560, 600, 601, 650, and 670 phones, IP_4000 parameters
affect SoundStation IP 4000 and 6000 phones, and IP_7000 parameters affect
SoundStation IP 7000 phones.
Attribute
Permitted
Values Interpretation
ind.led.x.index This is for internal usage only and should not be changed (this is
the logical index).
ind.led.x.class positive integer Assigns the class (defined in Classes <class/> on page A-82) for
this indicator.
ind.led.x.physNum This maps the logical index to a specific physical LED.
Attribute
Permitted
Values Interpretation
ind.gi.x.y.index This is for internal usage only and should not be changed (this is
the logical index).
ind.gi.x.y.class positive integer Assigns the class (defined in Classes <class/> on page A-82) for
this indicator.
ind.gi.x.y.physX IP 300: 0-19
IP 330: 0-101
IP 400: 0-122
IP 500: 0-159
IP 600: 0-319
IP 4000: 0-247
IP 7000: 0-255
For Graphic Icon type indicators, this is the x-axis location of the
upper left corner of the indictor measured in pixels from left to
right.