MeasuresCauseScreen example
26
Easy Setup and Operation
About the error message
• These error messages will be displayed when performing the measurements of Auto Setup and the automatic measurements
can not be completed because of the speaker arrangement, measurement environment, or other factors. Please check the
following matters, reset the pertinent items, and measure again. Be sure to turn off the AVR-5805CI’s power before checking
the speaker connections.
q The speakers required for producing suitable
reproduction have not been detected.
• The front L speaker was detected, but the
front R speaker was not detected.
• Only one channel of the surround (A) and
surround (B) speakers was detected.
• Sound was output from the R channel when
only one surround back speaker was
connected.
• The surround back or the surround (B) speaker
was detected, but the surround (A) speaker
was not detected.
If multiple errors occur, press the CURSOR
FF
or
GG
button to check the contents.
• Check that the pertinent speakers
are properly connected.
w The speaker polarity is connected in reverse.
If multiple errors occur, press the CURSOR
FF
or
GG
button to check the contents.
• Check the polarity of the pertinent
speakers.
• For some speakers, the screen
below may be displayed even though
the speakers are properly connected.
If so, select “Skip
0
”.
e There is too much ambient noise in the room
and the measurements cannot be made
accurately.
r The sound level that is output from the
speakers and/or subwoofer is too low.
• Either turn off the power of the
device that generated the noise
during the measurements or move
the device away.
•Try again at a time when it is quieter.
• Check the placement and orientation
of the loudspeakers.
• Adjust the subwoofer’s output level.
t The measurement microphone is not
connected, or all of speakers have not been
detected.
y The front L speaker was not detected.
• Connect the measurement microphone
to the SETUP MIC jack.
• Check the speaker connection.