151
Advanced Setup – Part 2
Check the parameter
1
Press the CURSOR
DD
or
HH
button to select
“Parameter Check” at the “Auto Setup / Room
EQ” menu, then press the
ENTER button.
• The “Parameter Check” screen appears.
• The results of the measured items can be checked.
• The EQ parameters that were set in Auto Setup can be
checked.
• This item is displayed, after the measurement result of the
“Auto Setup / Room EQ” is decided.
2
Press the CURSOR
DD
or
HH
button to select the
items, then press the
ENTER button.
• The verification screen appears.
4
Press the CURSOR
DD
or
HH
button to select “EQ
Parameter Check”, then press the
ENTER
button.
• The “EQ Parameter Check” screen appears.
AVR-5805CI
Speaker Microphone
Use the internal test tones
for mic amp calibration.
Pressure level with SPL meter at the
microphone point.
Adjust AVR volume SPL meter = 80 dB (C)
MIC AMP with mic
power supply ex.
mixer amp.
Measure the output level
and adjust the mic amp gain
to 120 mVrms using a RMS
volt meter.
120 mVrms
3
If the check ends, press the ENTER button
again.