_K==oÉãçíÉ=`çåíêçä=mêçíçÅçä
LED-PRO Remote Commands
Query:
IGM? in
Returns the Input Gamma for the specified input channel in the format
= n
S IGM 1 2.2 (Set Input gamma value to 2.2 for channel 1)
S IGM? 2 (Queries channel 2's Input gamma value.)
fe^qs=åååå
Description: Set Input Horizontal Active. The minimum and maximum limit is
dependent on the input resolution.
Parameters:
in - Input chnl [1-4]
nnnn - Input Horizontal Active: nnnn[(Actual Input H Active * 2/10,
minimum of 150) - +(Actual Input H Active * 6/5, maximum of Input H
Total - Input H Sync)]
Query:
IHATV? in
Returns the Input Horizontal Active in the format
= nnnn
S IHATV 1 1024 (Set Input Horizontal Active for channel 1 to 1024)
S IHATV? 1 (Queries Input Horizontal Active for channel 1)
femlp=åååå
Description: Set Input Horizontal Position. The minimum and maximum limit is
dependent on the input resolution.
Parameters:
in - Input chnl [1-4]
nnnn - Input Horizontal Position: nnnn[(Input H Sync) - +(H Total - H
Active)]
Query:
IHPOS? in
Returns the Input Horizontal Position in the format
= nnnn
S IHPOS 1 296 (Set Input Horizontal Position for channel 1 to 296)
S IHPOS? 1 (Queries Input Horizontal Position for channel 1)
feqlq^i=åååå
Description: Set Input Horizontal Total. The minimum and maximum limit is
dependent on the input resolution.
Parameters:
in - Input chnl [1-4]