AMX HDMI-UTPRO-0808 Stereo Receiver User Manual


 
HDMI UTPro WebConsole
72
Instruction Manual – HDMI-UTPRO-0808
4. Click Accept to send the command.
The response appears in the Replies field on the right.
Click Refresh to receive new replies (notifications) in the Replies field. New replies are added to the bottom
of the list.
Click Clear to clear the Replies field.
Click Cancel to exit the page without saving any changes.
To send commands to an HDMI-UTPRO-RX:
1.
From the Device drop-down menu, select the target Receiver (RX 1 - RX 8) – only those connected display in the
list.
2. Check to be sure the “Send as String” check box is not checked.
3. From the Port drop down menu, select the applicable port on the Receiver to receive the command.
Port 1: SEND_COMMANDs
Port 2: SERIAL (RS-232) SEND_COMMANDs
Port 3: IR SEND_COMMANDs
4. Enter the command in the Commands field on the left.
5. Click Accept to send the command.
The response appears in the Replies field on the right.
Click Refresh to receive new replies (notifications) in the Replies field. New replies are added to the bottom
of the list.
Click Clear to clear the Replies field.
Click Cancel to exit the page without saving any changes.
Device Configuration Page
Select Device Configuration from the Admin menu to access the Device Configuration page (FIG. 46). Use this page to
view/edit the device configuration for the HDMI UTPro. Note that this page has two tabs: Device Configuration and
Master Connection.
Device Configuration Tab
The Device Number field in this tab allows you to manually change the device number of the HDMI UTPro.
The default Device Number assigned to the HDMI UTPro is 5500 (in NetLinx Studio, the device number is 05500). The
default Device Numbers assigned to the HDMI-UTPRO-RX Receivers are 5501 through 5508. To change the device
number, enter the new device number and click Accept (or click Cancel to discard changes).
FIG. 46 Device Configuration page (Device Configuration tab)
Click to open the