1/99 SMV 3000 Transmitter User’s Manual 39
5.2 Establishing Communications, Continued
ATTENTION
Connecting the host computer to an SMV for on-line communications
requires Smartline Option Module consisting of a PC Card and Line
Interface Module.
SCT 3000 On-line
Connections to the
SMV
Table 8 provides the steps to connect the assembled SCT 3000 hardware
between the host computer and the SMV for on-line communications.
WARNING
When the transmitter’s end-cap is removed, the housing is not
explosionproof.
Table 8 Making SCT 3000 Hardware Connections
Step Action
1
With the power to the host computer turned off, insert the PC Card into
the type II PCMCIA slot on the host computer (see Figure 5-1).
ATTENTION To use the SCT 3000 in a desktop computer without a
PCMCIA slot, you must install a user-supplied
PCMCIA host adapter. Honeywell has performance-
qualified the following PCMCIA host adapters for use
with the SCT:
-- TMB-240 Single Slot Internal Front Panel Adapter
-- TMB-250 Dual Slot Internal Front Panel Adapter
-- GS-120 Greystone Peripherals, Inc.
-- GS-320 Greystone Peripherals, Inc.
CAUTION Do not insert a PC Card into a host computer’s
PCMCIA slot while the host computer is powered on.
2
Remove the end-cap at the terminal block side of the SMV and connect
the easy hooks or alligator clips at the end of the adapter cable to the
respective terminals on the SMV as follows:
• Connect the red lead to the positive terminal.
• Connect the black lead to the negative terminal.
ATTENTION The SCT 3000 can be connected to only one
SMV
at a time.
Continued on next page