Furuno RC-1500-1T Stereo System User Manual


 
SP - 11
SPECIFICATIONS OF THE AC/DC CHANGE-OVER UNIT
(RADIO SWITCH BOX)
1. BATTERY CHARGER (BC-6158)
(1) Applicable Battery 200AH Normal ship battery
(2) Power Source 100/110/115/220/230 VAC, 1 phase, 60 Hz or 24 VDC
(3) Output for Battery 24 VDC, 30 A nominal
(4) Charge/discharge Meter built in the radio console panel
(5) Control Panel built in the radio console
2. RECTIFIER (PR-850AR)
(1) Power Source 100/110/200/220 VAC, 1 phase, 50-60 Hz or 24 VDC
(2) Input Current 15 A or less (AC input), 30 A or less (DC input)
(3) Rush Current 80 A or less
(4) Output Voltage DC24 V ±10%, 30 A
(5) Peak Output Current 60 A (60 A output with 1 min AC or 40 A within 1 min DC)
(6) Ripple Voltage 100 mVp-p or less
(7) Insulation Resistance 500 VDC, 50 M
or more between AC input and chassis
3. RECTIFIER (PR-300)
(1) Power Source 100/110/200/220 VAC, 1 phase, 50-60 Hz or 24 VDC
(2) Input Current 2 A or less (AC input), 3.1 A or less (DC input)
(8) Rush Current 80 A or less
(3) Output Voltage 24 VDC ±10%, 7.5 A
(4) Peak Output Current 20 A (10 A output within 2H or 20 A within 15 min)
(5) Ripple Voltage 100 mVp-p or less
(9) Insulation Resistance 500 VDC, 50 M
or more between AC input and chassis