8. CHECKING, MAINTENANCE
WARNING
Do not open the equipment.
Hazardous voltage which can
cause electrical shock exists
inside the equipment. Only
qualified personnel should
work inside the equipment.
8.1 Daily Test
Authorities require that the equipment be checked daily for proper operation to ensure that it will
function properly in the event of distress.
Execute the daily test as below.
1. At the DSC standby screen or radiotelephone setting screen, press the [3/TEST] key to start
the test.
2. After several seconds the test results appear followed by the audio alarm. OK denotes
normal operation, and NG (No Good), error. For NG (No Good) contact your dealer for
advice.
: OK VER.XX* MAIN CPU
MODEM
RCVR1
RCVR2
REMOTE RT
REMOTE DP
: OK VER.XX*
: OK
: OK
: OK FS1562
: OK DP-6
**
DSC-60 daily test
**
MAIN CPU: ROM/RAM test executed and version no. displayed.
MODEM: DSP ROM and DSC signal loopback tests executed and
version no. displayed.
RCVR1: Distress/safety watch received tested.
RCVR2: Routine watch receiver (option) tested.
REMOTE RT: CAID of MIF command sent and received. Name of
equipment connected (if FURUNO make) and result appear.
(System setting RP PORT must be set for RT or MIF otherwise
nothing appears.)
REMOTE DP: CAID of MIF command sent and received. Name of
equipment connected (if FURUNO make) and result appear.
(Nothing appears when system setting NBDP PORT is OFF.)
Alarm: Distress alarm sounds for two seconds after completion
of test.
* XX = Version number