Furuno RC-1500-1T Stereo System User Manual


 
7-2
7.2 Alarm Menu
The Alarm menu enables/disables internal and external alarms. Note that the Distress/Urgency
alarm cannot be disabled. Press the [#/SETUP] key, select ALARM and press the [ENT] key to
display the Alarm menu.
****
Alarm setup
***
INTERNAL AUDIO ALARM
RCVD CALL
OLD POSITION
POSITION OLDER
EXT ALARM : DSTRS/URG
: ON
: ON
: 4.0 H
OFF
ON
OFF
ON
3.0
2.0
1.0
0.5
4.0
ROUTINE
ALL
OFF
DSTRS/URG
35˚00.000N 135˚00.000E 23:59
WATCH KEEPING
2187.5
4207.5
6312.0
8414.516804.5
12577.0
DISTRESS
ROUTINE
2177.0
4219.5
6331.0
16903.0
12657.0
VOLUME
Warning:
Update position
Default: ON
Default: ON
Default: 4.0 hours
Default: DSTRS/URG
Disables/enables alarm for received Safety,
Ship's Business and Routine messages.
Alarm is output when position is older by the
number of hours set here.
Sets type of message to be output to the
IC-303 incoming Indicatior.
DSTRS/URG: Distress or urgency
message output upon
receipt.
ROUTINE: Routine message output
upon receipt.
ALL: All messages output.
OFF: No output.
Note: Alarm for Distress and Urgency
messages cannot be disabled, and its
decibel level is fixed at 75-85 dB.
Note: Authorities require that position be
updated at least every four hours.
22
AUTO ACK
or
to set.
or
to set.
or
to set.
8436.5
Disables/enables old position alarm in manual
position entry mode, which alerts the operator
when position data is older by the number of
hours or minutes set in the Position Older field.
Message shown when position is
older than preset on the Alarm
setup menu.