Figure 26. Filter Dialog Box, Filter Not Bypassed
Above the graph, each filter has a "handle" (circled in red above) placed directly
above the cutoff or center frequency whose number corresponds to the filter number
(outlined in red). Clicking a handle or clicking the table row brings focus to that filter.
<Click+hold+dragging> the handle horizontally changes the cutoff or center frequency to
a new position on the x axis.
The table below shows each filter type with default parameter settings. The table
immediately following shows the possible range for each parameter.
Type Frequency Parameter 1 Parameter 2
High Pass 100 Hz Slope: 6dB N/A
Low Pass 10000 Hz Slope: 6dB N/A
Bass 100 Hz Boost/Cut: 0.0dB Slope: 6dB
Treble 8000 Hz Boost/Cut: 0.0dB Slope: 6dB
Parametric 1000 Hz Boost/Cut: 0.0dB Q: 1.0
Filter Parameter Settings Range
Frequency 20 Hz to 20 kHz
Boost/Cut -24.0dB to +24.0dB
Q (Parametric EQ only) 0.707 to 15.000
Slope (HP & LP filters only) 1st Order (6dB) and 2nd Order (12dB)
DMP128 • Software Control 35