Extron electronic DMP 128 Stereo System User Manual


 
DMP128 Hardware Reset Modes
DMP128 Reset Mode Summary
Mode Mode Activation Result Purpose/Notes
Use Factory Firmware
1
Hold the reset button while applying
power.
NOTE: After a mode 1 reset, update the
DMP128 firmware to the latest version.
DO NOT operate the firmware version that
results from this mode reset.
The DMP128 reverts to the factory
default firmware.
Event scripting does not start if
the DMP128 is powered on in this
mode. All user files and settings
(drivers, IP settings, and similar
items) are maintained.
NOTE: If you do not want to update the
firmware or perform a mode1 reset by
mistake, cycle power to the DMP128 to
return to the firmware version running prior
to the reset.
This mode reverts to the
factory default firmware
version if incompatibility
issues arise with user-
loaded firmware.
NOTE: User-defined Web pages
may not work correctly if using
an earlier firmware version.
Run/Stop
Events
3
With power on, press and hold the
Reset button until the Power LED
blinks once (3sec.), then release
and within 1 second press Reset
momentarily (<1 sec).
NOTE: The mode will not be entered unless
the momentary press occurs within one
second.
Mode 3 toggles events on or off.
Front panel level indicators blink
twice to indicate events has toggled
on, or three times to indicate event
logging has toggled off.
Useful for troubleshooting
Reset all
IP Settings
4
Press and hold the Reset button for
about 6sec. until the Power LED
blinks twice (once at 3 sec., again
at 6 sec.), then release and within
1 second press Reset momentarily
(<1sec.).
NOTE: The mode will not be entered unless
the momentary press occurs within one
second.
Mode 4:
•  Enables ARP capability.
•  Set the IP address to default.
•  Sets the subnet to default.
•  Sets the gateway address to
default.
•  Sets port mapping back to
default.
•  Turns DHCP off.
•  Turns events off.
Enables resetting IP
address information using
ARP and MAC address.
Reset to
Factory Defaults
5
Press and hold the Reset button for
about 9 sec. until the Power LED
blinks three times (once at 3 sec.,
again at 6 sec., again at 9 sec.),
then release and within 1 second
press Reset momentarily (<1sec.).
NOTE: The mode will not be entered unless
the momentary press occurs within one
second.
Mode 5 performs a complete
reset to factory defaults, except
for firmware:
•  Does everything mode 4 reset
does.
•  All mix-points are muted and
set to 0dB.
•  All outputs are unmuted and
set to 0dB.
•  DSP Processing returned to
defaults and bypassed.
•  All inputs are muted and set to
0dB.
•  All presets and group master
memory cleared.
Useful to start over with
configuration or uploading,
and to replace events.
DMP128 • Reference Information 152