Reset Actuator and LED
A recessed button on the rear panel initiates several reset modes. The rear panel LED
blinks to indicate the reset mode.
100-240 ~ 0.6A
RESET
LAN
3
7
2
6
1
5
MIC/LINE INPUTS
Tx Rx
RS-232
DIGITAL I/O
123 4 5
MIC
+48V
132
DMP 128
Digital Matrix
Processor
EXP
50/60 HZ
4
8
4
5768
910
11 12
678
9 10
11 12 13 14 15 16 17 18 19 20
O
U
T
P
U
T
S
2134
6578
j
Rear Panel
Figure 9. Reset Button and LED
Hardware Reset Modes:
NOTE: The reset modes listed below will close all open IP and Telnet connections,
and close all sockets.
With power on, when the reset button is held down, every three seconds the rear panel
LED will pulse (blink). At the first blink Mode 3 is available, at the second blink Mode 4 is
available and the third blink indicates Mode 5 is available. The reset modes have separate
and distinct functions outlined below (see “DMP128 Hardware Reset Modes” on
page152).
MODE 1 — Firmware reset: Disconnect power to the DMP128. Press and hold the
reset button while applying power to return the firmware to the version shipped with the
unit from the factory. Event scripting will not start when powered on in this mode. This
allows recovering a unit with incorrect or corrupt firmware.
All user files and settings are maintained. Some user web pages may not work correctly if
returning the unit to an earlier firmware release.
MODE 3 — Events reset: With power on, press and hold the reset button until the reset
LED blinks once (~3 seconds). Release the reset button, then within one(1) second press
it again to toggle events On or Off, depending on the current state.
If the event logging is currently stopped, following the momentary (<1 sec.) press, the
reset LED will flash twice indicating events logging has begun.
If any events are currently running, following the momentary (<1sec.) press, the reset LED
will flash three times indicating the events logging has stopped.
Each flash will last for 0.25 seconds. If the second momentary press does not occur
within 1 second, Mode 3 is exited.
MODE 4 — IP Address reset: With power on, press and hold the reset button about
6seconds until the reset LED blinks twice. Release the reset button, then within 1
second, press it again to reset the IP settings.
Mode 4 will:
• Enable ARP program capability
• Set IP back to factory default IP address (192.168.254.254)
• Set Subnet back to factory default (255.255.0.0)
• Set Gateway back to factory default (0.0.0.0)
• Set Digital I/O Port mapping back to factory default
• Turn DHCP off
• Turn events off
If a second momentary press does not occur within 1 second, the reset will be ignored.
DMP128 • Operation 12