Agilent Technologies N9010A Stereo System User Manual


 
Chapter 13 167
cdma2000 Measurement Application
Measurements
Description Specifications Supplemental Information
QPSK EVM
25 dBm ML
a
15 dBm
20 to 30° C
a. ML (mixer level) is RF input power minus attenuation
RF input power range is accordingly
determined to meet Mixer level.
EVM
Range
0 to 25%
Floor 1.6%
Accuracy
b
b. The accuracy specification applies when the EVM to be measured is well above the measurement floor.
When the EVM does not greatly exceed the floor, the errors due to the floor add to the accuracy errors.
The errors due to the floor are noise-like and add incoherently with the UUT EVM. The errors depend
on the EVM of the UUT and the floor as follows: error = sqrt(EVMUUTP2P + EVMsaP2P)
EVMUUT, where EVMUUT is the EVM of the UUT in percent, and EVMsa is the EVM floor of the
analyzer in percent.
±1.0%
I/Q origin offset
DUT Maximum Offset
Analyzer Noise Floor
10 dBc (nominal)
50 dBc (nominal)
Frequency Error
Range
±30 kHz (nominal)
Accuracy
±5 Hz + tfa
c
c. tfa = transmitter frequency × frequency reference accuracy
500 Hz (nominal)