Intel SBCEFCSW Stereo Receiver User Manual


 
84 Intel Blade Server Fibre Channel Switch Module SBCEFCSW / FC Expansion Card SBFCM Guide
Zone sets
A zone set is a named group of zones. A zone can be a member of more than one zone set. All zones that are
not members of a zone set belong to the orphan zone set. The orphan zone set is saved to the switch module.
Each switch module in the fabric maintains its own zoning database containing one or more zone sets. This
zoning database resides in nonvolatile or permanent memory and is therefore retained after a reset. For
information about displaying the zoning database, see “Configured Zonesets Data window” on page 96.
To apply zoning to a fabric, select a zone set and activate it. When you activate a zone set, the switch module
distributes that zone set to every switch in the fabric. Therefore, every switch module in the fabric will have
identical active zone sets. For information about displaying the active zone set, see “Active Zoneset Data
window” on page 82.
Zoning database
Each switch module has its own zoning database. The zoning database is made up of all aliases, zones, and
zone sets that have been created on the switch or received from other switch modules. The switch module
maintains two copies of the zoning database: one copy is maintained in temporary memory for editing
purposes; the second copy is maintained in permanent memory. Zoning database edits are made on an
individual switch basis and are not propagated to other switch modules in the fabric when saved.
The Auto Save zoning configuration parameter controls whether the temporary zoning database is
automatically saved in permanent memory. For more information about the Auto Save parameters, see
“Zoning configuration.”
The zoning limits for a fabric are:
Maximum number of zonesets is 256
Maximum number of zones is 256
Maximum number of aliases is 256
Maximum number of members per zone is 2000
Maximum number of members per alias is 2000
Maximum total number of zone and alias members is 2000
Maximum total number of zone set members is 1000
Zoning configuration
You can set the zoning configuration parameters using the SAN Utility or the Set Zoning Config command.
For information about zoning configuration using the SAN Utility, see “Using the Zoning Config window” on
page 85 and “Set Config command” on page 26.
The following parameters make up the zoning configuration:
• Auto Save
Default Visibility
Auto save
The Auto Save parameter determines whether changes to the active zone set that a switch module receives
from other switches in the fabric are saved to permanent memory on that switch module. Changes are saved
when an updated zone set is activated. Zoning changes are always saved to temporary memory. However, if
Auto Save is enabled, the switch module firmware saves changes to the active zone set in both temporary and
permanent memory. If Auto Save is disabled, changes to the active zone set are stored only in temporary
memory.
Default visibility
The Default Visibility parameter determines the level of communication that is permitted between devices
when there is no active zone set. The default visibility parameter can be set differently on each switch module.
When default visibility is enabled (set to All) on a switch module, all ports on the switch can communicate
with all ports on switch modules that also have the Default Visibility parameter set to Enabled. When default
visibility is disabled (set to None) on a switch module, none of the ports on that switch module can
communicate with any other switch in the fabric.