20 Intel Blade Server Fibre Channel Switch Module SBCEFCSW / FC Expansion Card SBFCM Guide
Quit command
Closes the Telnet session.
Authority
User
Syntax
quit, exit, or logout
Reset command
Resets the switch and port configuration parameters.
Authority
Admin
Syntax
reset
config [config_name]
factory
port [port_number]
snmp
switch (default)
system
zoning
Keywords
config [config_name]
Resets the configuration given by [config_name] to the factory default values for switch, port, alarm
threshold, and zoning configuration. This keyword clears all zoning definitions. If [config_name]
does not exist on the switch, a configuration with that name is created. If you omit [config_name], the
active configuration is reset. You must activate the configuration or reset the switch for the changes to
take effect. See Table 2 on page 21 through Table 4 on page 22.
factory
Resets switch, alarm threshold, port, SNMP, zoning configuration, and blade server configuration
settings to the factory default values. The switch configuration is activated automatically. See Table 2
on page 21 through Table 6 on page 23.
port [port_number]
Reinitializes the port given by [port_number]. Ports are numbered beginning with 0. For more
information, see Table 37 on page 124.
snmp
Resets the SNMP configuration settings to the factory default values. See Table 5 on page 23 for
SNMP configuration default values.
switch
Reinitializes the switch. This is the default. This command also closes the Telnet session.
system
Resets the blade server configuration settings to the factory default values. See Table 6 on page 23 for
configuration default values.
zoning
Clears the zoning database and deactivates the active zone set. The zoning configuration values
remain unchanged.