Extron electronic USP 507 Stereo System User Manual


 
B-2
USP 507 Ethernet Connection
Ethernet Connection
Ethernet Link
The rear panel Ethernet connector on the USP 507 can be connected to an
Ethernet LAN or WAN. This connection makes SIS control of the unit
possible using a computer connected to the same LAN.
Ethernet connection
The Ethernet cable can be terminated as a straight-through cable or a crossover
cable and must be properly terminated for your application (figure B-1).
Crossover cable — Direct connection between the computer and the USP 507.
Patch (straight) cable — Connection of the USP 507 to an Ethernet LAN.
12345678
RJ-45 Connector
Insert
Twisted
Pair Wires
Pins:
Straight-through Cable
(for connection to a switch, hub, or router)
End 1 End 2
Pin Wire Color Pin Wire Color
1 white-orange 1 white-orange
2 orange 2 orange
3 white-green 3 white-green
4 blue 4 blue
5 white-blue 5 white-blue
6 green 6 green
7 white-brown 7 white-brown
8 brown 8 brown
Crossover Cable
(for direct connection to a PC)
End 1 End 2
Pin Wire Color Pin Wire Color
1 white-orange 1 white-green
2 orange 2 green
3 white-green 3 white-orange
4 blue 4 blue
5 white-blue 5 white-blue
6 green 6 orange
7 white-brown 7 white-brown
8 brown 8 brown
Figure B–1 — RJ-45 connector pinout tables
Default address
To access the USP 507 via the Ethernet port, you need the unit’s IP address. If the
address has been changed to an address comprised of words and characters, the
actual numeric IP address can be determined using the ping utility. If the address
has not been changed, the factory-specified default is 192.168.254.254.
Ping can also be used to test the Ethernet link to the USP 507
.
Ping to determine Extron IP address
The ping utility is available at the command (Cmd) prompt. Ping tests the
Ethernet interface between the computer and the USP 507. Ping can also be used
to determine the actual numeric IP address from an alias and to determine the Web
address.
Ping the device as follows:
1
. From the Windows Start menu, select Run... . The Run window opens.
2. In the Open text field, enter command.
ACT