Extron electronic USP 507 Stereo System User Manual


 
USP 507 • SIS Programmer’s Guide
4-19
Command ASCII (Telnet)
(host to processor)
URL Encoded (Web)
(host to processor)
Response
(processor to host)
Additional
description
Configure redirect mode
EX12%
*
X14#
*
X14$
*
X13!
CD
}
W
X12%
%2A
X14#
%2A
X14$
%2A
X13!
CD
|
Cpn
X12%•
Ccd
X14#
,
X14$
,
X13!]
Terminate redirect mode
EX12%
*0CD
}
W
X12%
%2A0CD
|
Cpn
X12%•
Ccd00000,00000,
00000L
]
Read redirect mode
EX12%
CD
}
W
X12%
CD
|
X14#
,
X14$
,
X13!]
Ethernet data port
Set current conn port timeout
E
0*
X14@
TC
}
W0%2A
X14@
TC
|
Pti0*
X14@]
Read current conn port timeout
E
0TC
}
W
0
TC
| X14@]
Set global IP port timeout
E
1*
X14@
TC
}
W1%2A
X14@
TC
|
Pti1*
X14@]
Read global IP port timeout
E
1TC
}
W1TC
| X14@]
Directories
Change/create directory
Epath/directory/CJ}
W
path%2Fdirectory%2FCJ
| Dir•path/directory/]
Back to root directory
E/CJ}
W
%2FCJ
| Dir•/]
Up one directory
E~CJ}
W%
2E
%
2ECJ
| Dir•path/directory/]
View current directory
ECJ}
WC
J
| path/directory/]
directory = A text string drawn from the alphabet (A-Z), digits (0-9), minus sign/hyphen (-). No blank or space characters are permitted as part of the name.
No distinction is made between upper and lower case. The first character must be an alpha character.
N
A directory does not truly exist until a file has been copied into that path.
Unlike various PC operating systems, a file and directory on the Extron product are allowed to have the same name.
The current directory is a per-connection setting. It begins at the root for each IP session.
N
X12%
= Specific serial port number: 01-03, 01 = COM1, 02 = COM2, 03 = COM3
X13! =
Parameter (#L or #D) to set either the Length of message to receive or the Delimiter value. # = byte count (for L) or # = a single ASCII character
expressed in decimal form (for D). The parameter is case sensitive. Byte count is 0 to 32767, (default = 0).
X14@ =
IP connection timeout period specified in 10-second steps , 1 - 65000, (default = 30 = 300 seconds). If no data is received in the specified period, the connection closes.
X14#
= Redirection status: 0 = no redirection, 1 - 3 = redirect serial communication
X14$
= Timeout period in tens of milliseconds for serial data pass-through mode, range = 1 - 32767, (default = 10 = 100 ms)